Choose a standard tin for a product that users brush on or pour. For a pressurized spray, start with a stock aerosol can that fits the formulation and filling line. Consider a custom aerosol can when available sizes, valves or decoration cannot meet the brief.
A custom aerosol can isn’t a prettier tin. It’s a metal argument with your fill line, and somebody always loses.
Custom Aerosol Can: Quick Answers Before You Spec
- Gauge and Wall: Specify finished wall thickness and tolerance in the drawing.
- Täytä tilavuus: Allow for liquid expansion at the temperature specified for the package.
- Räjähdyspaine: Use the applicable container test and the pressure of the complete formulation.
- Valve and Gasket: Confirm valve dimensions and gasket compatibility with the formulation.
- Lining Fit: Check whether the formulation needs an internal coating.
- Vaatimustenmukaisuus: Identify the destination and transport mode before selecting the container specification.
Standard Tins vs Custom Aerosol Cans

Picking a can sounds simple until fill volume, venttiilit, and lead times start pulling in different directions. FANXUN tarjoaa maalipurkkeja for conventional coatings and tinaiset aerosolipurkit spray-tuotteille. Compare stock and custom options within the appropriate packaging family.
Standard Tins
Stock sizes are the whole appeal. Ask which sizes are available, whether existing tooling can be used and what the delivered price would be for your first run.
The trade-offs show up fast, vaikka:
- Speed and price, kyllä
- confirm lead time and minimum order size
- request the tinplate specification for repeat orders
- Sovita ja viimeistele, not so much
- for a stock aerosol format, check which venttiilit sovi
- fill volume bends around the can, not the other way round
- valmistuksen yleiskustannukset creeps back in through workarounds
A stock format can suit test batches if it uses the dispensing system planned for production.
Custom Aerosol Cans
Custom work may involve printing on an existing body or changing the body dimensions. Ask which diameter, height and valve combinations are available before budgeting for tooling.
Varma, printing expenses ja minimum run volumes bite early. Design complexity drags component complexity along for the ride — artwork has to wrap a curved surface, ja pintakäsittely choices multiply fast. Spring for finishing options and the can reads as yours, not as catalog stock.
Ask FANXUN to compare an existing format with the proposed custom design. Include the target fill, annual volume and artwork in your enquiry.
Levels of Tinplate Thickness Explained
Thin walls save weight, but a drawing alone cannot establish how the finished can will perform. Tarkista aerosolitölkin valmistusprosessi alongside the material specification and test records.

Reading Gauge Numbers as Wall Thickness
Ask the supplier to identify the measurement points and tolerances on the finished drawing. For a DOT 2Q container, the minimum wall thickness on 0.008 tuumaa. Check how the drawing treats each component:
- Body wall — compare the measured and specified thickness
- Shoulder — identify the formed area on the drawing
- Dome — confirm which pressure-design päättyy the specification requires
Compare the body and end specifications separately. Record the units and suvaitsevaisuus alongside each measurement.
How Much Burst Pressure Does a Lighter Can Hold?
Wall thickness alone does not give a burst rating. USA:lle. limited-quantity metal aerosols under § 173.306(a)(3), the burst criterion uses the equilibrium pressure of the contents klo 54.4 °C. For a DOT 2Q can, request the separate lot test record for the container with its end assembled.
Deep Drawing Limits at Each Grade
For drawn components, vahvistaa venymä ja vetolujuus, set the depth to suit the grade, then trial a small batch before full tooling. For DOT 2Q cans, tarkista materiaalivaatimukset for acceptable plate and injurious defects.
Choosing a Lining for the Formulation
Arvioida kemiallinen yhteensopivuus käyttäen todellista formulaatiota, exposed metal and any proposed coating. If the supplier proposes an epoxy phenolic lining, ask for results from filled samples made with that lining.
5 Checks Before You Order Custom Aerosol Cans

Use these five checks to agree on the specification with the can supplier and filler before you commit volume.
Is Your Fill Volume Matched to the Can Dimensions?
- Täytä tilavuus has to sit under true overflow capacity
- Under § 173.306(a)(3), liquid must leave headspace at 54.4 °C
- Include the ponneaine when assessing the filled package
- Tarkista uudelleen tölkin mitat against the pakkausten suunnittelu drawings before tooling gets cut
Verify Valve and Gasket Compatibility
Tarkista valve parameters with the filler and check seal materials against both solvent and propellant. A buna gasket that swells is a leak waiting to happen.
- Venttiili crimp diameter against the can neck
- Elastomeeri swell test with the intended formulation
- Tiivisteen eheys watched at storage temperature
Get this wrong on a custom spray can run and your ponneaine escapes quietly, one can at a time.
Pressure Testing Before the Production Run
Nobody wants a räjähdyspaine surprise halfway through a tuotantoajo.
- Agree with the filler on the required filled-container leak test and any permitted alternative
- For the standard U.S. water bath test, the target internal pressure depends on fill conditions
- Check for leakage and permanent muodonmuutos
- Request separate records for the empty-container lot and the filled production run
Corrosion Inhibitor vs. Product Chemistry
Review the metal, lining and any proposed korroosionestoaine yhdessä. Ask which changes in the stored product would indicate a compatibility problem.
- pH-taso drift where relevant to the formulation
- Hapetus during warehouse storage
- Todellinen säilyvyysaika from a filled sample, ei arvaus
Confirm the Transport Specification and Shipping Documents
Identify the shipping route before requesting marks or paperwork.
- USA:lle. kuljetus, identify the proper shipping name and hazard class in the Hazardous Materials Table.
- Tarkista rules for each transport mode. ADR applies to international road carriage on routes within its scope.
- When U.S. shipping papers are required, tarkista shipping description, including the identification number.
Confirm the applicable exceptions with the shipper before releasing the order.
Viitteet
- 49 CFR § 178.33a-7 – Seinän paksuus — Cornell Legal Information Institute
- 49 CFR § 178.33a-6 – Manufacture — Cornell Legal Information Institute
- 49 CFR § 173.306 – Painettuja kaasuja rajoitettu määrä — Cornell Legal Information Institute
- 49 CFR § 178.33a-8 – Tests — Cornell Legal Information Institute
- 49 CFR § 178.33a-5 – Materiaali — Cornell Legal Information Institute
- 49 CFR § 173.24 – Yleiset vaatimukset pakkauksille ja pakkauksille — Cornell Legal Information Institute
- Tulkinta 98-0350 - U.S. Liikenneministeriö
- 49 CFR § 172.101 – Purpose and use of the hazardous materials table — Cornell Legal Information Institute
- Moving dangerous goods: Rules for different types of transport — GOV.UK
- 49 CFR § 172.202 – Description of hazardous material on shipping papers — Cornell Legal Information Institute